ELECTRONIC STATIC FUEL DISPENSING UNIT (NTR /01)

  • AVAILABLE MODELS: PRESET & NON PRESET
  • DIMENSIONS: 84cm X 41cm X 15.9cm
  • WEIGHT: 172 kg (Approx)
  • ACCURACY CLASS: 0.5%
  • FLOW RATE: UPTO 9O LPM
  • TYPE: Positive Displacement Meter
  • BODY MATERIAL: CRCA SHEET
  • REPEATABILITY: 100%
  • DISPLAY: Electronic register unit with 6-digit LCD display
  • PRINTER: YES
  • TOTALIZER: BOTH ELECTRONIC & MECHANICAL
  • CERTIFICATION: LEGAL METROLOGY GOV. OF INDIA
  • MOTOR: 0.75 HP
  • INPUT CURRENT: 220 VOLT AC
  • NOZZLE: MANUAL & AUTOSHUTOFF (AS PER CUSTOMER NEED)

  • USAGE: STATIC FUEL DISPENSING                       
  • MEASURES & MONITOR- LIKE LDO, HSD, KEROSENE, FURNACE OIL, DIESEL, BIO DIESEL, TRASFORMER OIL,DEF (TO BE MENTIONED WHEN ORDERED) ETC.

Electronic Static Fuel Dispensing Unit – Model NTR/01

The Electronic Static Fuel Dispensing Unit (Model NTR/01) is a precision-engineered fuel dispensing system designed for stationary fuel dispensing applications where accuracy, reliability, and operational efficiency are essential. Available in both Preset and Non-Preset models, the unit is equipped with a Positive Displacement (PD) Meter that delivers an accuracy class of ±0.5% with 100% repeatability, ensuring precise fuel measurement and consistent dispensing performance. The dispenser supports flow rates of up to 90 litres per minute (LPM) and features an electronic register unit with a 6-digit LCD display for clear and accurate transaction monitoring. An integrated thermal printer enables instant receipt generation, while both electronic and mechanical totalizers provide secure and reliable lifetime fuel dispensing records.

Manufactured from high-quality CRCA sheet, the dispenser has overall dimensions of 84 cm × 41 cm × 159 cm and weighs approximately 172 kg, making it a robust solution for continuous industrial use. The system is powered by a 0.75 HP motor operating on a 220V AC single-phase power supply, ensuring dependable performance under demanding operating conditions. It is certified by the Legal Metrology Department, Government of India, guaranteeing compliance with statutory standards for commercial fuel dispensing. The unit is available with manual or automatic shut-off nozzles, depending on customer requirements, providing safe, efficient, and convenient operation.

Designed specifically for static fuel dispensing, the Electronic Static Fuel Dispensing Unit (NTR/01) accurately measures, monitors, and dispenses a wide range of petroleum and industrial fuels, including LDO, HSD, kerosene, furnace oil, diesel, biodiesel, transformer oil, and DEF (to be specified at the time of order). It is ideally suited for industrial plants, manufacturing facilities, transport depots, mining operations, power plants, fleet management systems, fuel storage terminals, agricultural establishments, and institutional fuel dispensing applications, delivering reliable performance, precise metering, regulatory compliance, and long service life.

After Sale Service

Need after-sales support? contact our service team via phone or email for quick assistance.

At Neogi, your satisfaction is our priority. We offer comprehensive after-sales support for all our products, including expert technical assistance, maintenance guidance, and prompt service support.

After Sale Service
FAQ

Everything You Need To Know

The line filter and the BLDC pump's inbuilt filter should be cleaned once every week or more frequently if the fuel quality is poor. Regular cleaning ensures smooth fuel flow, accurate dispensing, and extends the life of the pump.

Maintaining a minimum fuel level (dead stock) prevents the pump from drawing air. Running the tank too low can cause suction problems, inaccurate fuel measurement (air counting), and may damage the pump and flow meter.

A 6 sq. mm or larger cable is recommended for all electrical connections. Proper cable sizing minimizes voltage drop and ensures the pump receives the required 12V DC power for reliable operation.

The vehicle engine should be started before dispensing so the alternator can continuously charge the battery while the pump is operating. This helps maintain a stable voltage supply and improves pump performance.

Yes. The vehicle should remain completely stationary and kept in Neutral during dispensing. This ensures safe operation and accurate fuel measurement.

Switching off the pump after every dispensing operation prevents unnecessary power consumption, reduces wear on the pump, and increases the overall life of the system.

The fuel tank should be thoroughly cleaned before first use and periodically during operation. Clean fuel free from dust, rust, water, or other foreign particles helps protect the pump, flow meter, filters, and dispensing system from damage.

Running the tank dry can cause the pump to draw air instead of fuel. This may lead to suction failure, inaccurate dispensing, air counting, and can seriously damage the Neogi Flow Scope and associated accessories.

No. The flow meter, controller, and other system components should never be tampered with. Unauthorized modifications can affect dispensing accuracy, damage the equipment, void the warranty, and compromise safety.

Suction problems are generally caused by: • Low fuel level in the tank. • Clogged line filter or pump filter. • Dirty fuel or contaminated tank. • Air entering the suction line. • Improper electrical wiring causing low voltage.

To maximize system life: • Clean both filters weekly. • Use clean, contamination-free fuel. • Maintain adequate fuel in the tank. • Use the recommended electrical cable size. • Switch off the pump after use. • Never allow the tank to run dry.

For optimum performance: • Weekly: Clean the line filter and BLDC pump filter. • Daily: Check fuel level and inspect for leaks. • Periodically: Clean the fuel tank and inspect electrical wiring and hose connections.

Check the following before requesting service: • Ensure sufficient fuel is available in the tank. • Clean the line filter and pump filter. • Verify the battery voltage is approximately 12V DC. • Check all electrical connections. • Ensure there are no air leaks or blockages in the suction line. If the issue persists, contact the NTR India service team for technical assistance.

Yes. Fuel contaminated with dust, rust, water, or other foreign particles can clog filters, reduce flow rate, affect meter accuracy, and damage internal components. Always use clean fuel from reliable sources.