STATIC FUEL DISPENSER (NTR/11)

  • High-precision Positive Displacement (PD) Meter for accurate fuel measurement.
  • Accuracy Class 0.5 with 100% repeatability for consistent dispensing performance.
  • Available in Preset and Non-Preset configurations.
  • Flow rate ranging from 5 to 85 Litres Per Minute (LPM).
  • Legal Metrology Certified by the Government of India.
  • Bright 6-digit LCD electronic display for easy reading.
  • Dual Electronic and Mechanical Totalizers for secure volume tracking.
  • Integrated thermal printer for dispensing receipts and transaction records.
  • Heavy-duty CRCA steel body designed for durability and corrosion resistance.
  • Powerful 0.75 HP inbuilt motor operating on 220V AC Single Phase supply.
  • Compatible with Manual and Automatic Shut-Off Nozzles.

N/A

The NTR/11  Electronic fuel dispenser with Pump is a compact, high-precision static fuel dispensing system engineered for accurate, reliable, and efficient fuel dispensing across industrial and commercial applications. Equipped with a Positive Displacement (PD) Meter, the system delivers Accuracy Class 0.5 performance with excellent repeatability, ensuring precise measurement for every dispensing operation.

Built with a rugged CRCA steel enclosure, the NTR/11 is designed for long service life in demanding operating environments. It features an inbuilt 0.75 HP motor, a 6-digit electronic LCD register, dual electronic and mechanical totalizers, and an integrated thermal printer for dispensing records. The dispenser is available in both Preset and Non-Preset models, allowing users to select the configuration best suited to their operational requirements.

The NTR/11 can be connected to above-ground or underground fuel storage tanks, making it an ideal solution for fixed fuel dispensing installations. Customers can also choose between manual and automatic shut-off nozzles depending on application requirements.

Designed for continuous, dependable operation, the NTR/11 is widely used in construction projects, mining operations, manufacturing facilities, fleet yards, agricultural sites, workshops, fuel storage depots, and other industrial installations requiring accurate fuel dispensing.

After Sale Service

Need after-sales support? contact our service team via phone or email for quick assistance.

At Neogi, your satisfaction is our priority. We offer comprehensive after-sales support for all our products, including expert technical assistance, maintenance guidance, and prompt service support.

After Sale Service
FAQ

Everything You Need To Know

The line filter and the BLDC pump's inbuilt filter should be cleaned once every week or more frequently if the fuel quality is poor. Regular cleaning ensures smooth fuel flow, accurate dispensing, and extends the life of the pump.

Maintaining a minimum fuel level (dead stock) prevents the pump from drawing air. Running the tank too low can cause suction problems, inaccurate fuel measurement (air counting), and may damage the pump and flow meter.

A 6 sq. mm or larger cable is recommended for all electrical connections. Proper cable sizing minimizes voltage drop and ensures the pump receives the required 12V DC power for reliable operation.

The vehicle engine should be started before dispensing so the alternator can continuously charge the battery while the pump is operating. This helps maintain a stable voltage supply and improves pump performance.

Yes. The vehicle should remain completely stationary and kept in Neutral during dispensing. This ensures safe operation and accurate fuel measurement.

Switching off the pump after every dispensing operation prevents unnecessary power consumption, reduces wear on the pump, and increases the overall life of the system.

The fuel tank should be thoroughly cleaned before first use and periodically during operation. Clean fuel free from dust, rust, water, or other foreign particles helps protect the pump, flow meter, filters, and dispensing system from damage.

Running the tank dry can cause the pump to draw air instead of fuel. This may lead to suction failure, inaccurate dispensing, air counting, and can seriously damage the Neogi Flow Scope and associated accessories.

No. The flow meter, controller, and other system components should never be tampered with. Unauthorized modifications can affect dispensing accuracy, damage the equipment, void the warranty, and compromise safety.

Suction problems are generally caused by: • Low fuel level in the tank. • Clogged line filter or pump filter. • Dirty fuel or contaminated tank. • Air entering the suction line. • Improper electrical wiring causing low voltage.

To maximize system life: • Clean both filters weekly. • Use clean, contamination-free fuel. • Maintain adequate fuel in the tank. • Use the recommended electrical cable size. • Switch off the pump after use. • Never allow the tank to run dry.

For optimum performance: • Weekly: Clean the line filter and BLDC pump filter. • Daily: Check fuel level and inspect for leaks. • Periodically: Clean the fuel tank and inspect electrical wiring and hose connections.

Check the following before requesting service: • Ensure sufficient fuel is available in the tank. • Clean the line filter and pump filter. • Verify the battery voltage is approximately 12V DC. • Check all electrical connections. • Ensure there are no air leaks or blockages in the suction line. If the issue persists, contact the NTR India service team for technical assistance.

Yes. Fuel contaminated with dust, rust, water, or other foreign particles can clog filters, reduce flow rate, affect meter accuracy, and damage internal components. Always use clean fuel from reliable sources.